Reorganize driver capabilities

pull/4/head
Diego Barrios Romero 2018-11-16 17:25:24 +01:00
parent 34f32ee067
commit 30cb5566d7
2 changed files with 31 additions and 25 deletions

View File

@ -9,23 +9,26 @@ This driver allows you to:
- Read and set date and time in 12-hour and 24-hour format. See: `get_datetime`. - Read and set date and time in 12-hour and 24-hour format. See: `get_datetime`.
- Read and set date and time individual elements. For example, see: `get_year`. - Read and set date and time individual elements. For example, see: `get_year`.
- Enable and disable the real-time clock. See: `enable`. - Enable and disable the real-time clock. See: `enable`.
- Read the temperature. See `get_temperature`.
- Force a temperature conversion and time compensation. See `convert_temperature`.
- Read the busy status. See `is_busy`. - Read the busy status. See `is_busy`.
- Read whether the oscillator is or has been stopped. See `has_been_stopped`. - Read whether the oscillator is or has been stopped. See `has_been_stopped`.
- Clear the has-been-stopped flag. See `clear_has_been_stopped_flag`. - Clear the has-been-stopped flag. See `clear_has_been_stopped_flag`.
- Set the aging offset. See `set_aging_offset`. - Set and read the aging offset. See `set_aging_offset`.
- Enable and disable the 32kHz output. See `enable_32khz_output`.
- Select the function of the INT/SQW output pin. See `use_int_sqw_output_as_interrupt`. - Select the function of the INT/SQW output pin. See `use_int_sqw_output_as_interrupt`.
- Enable and disable the square-wave generation. See `enable_square_wave`. - Wave generation:
- Select the square-wave frequency. See `set_square_wave_frequency`. - Enable and disable the square-wave generation. See `enable_square_wave`.
- Set alarms 1 and 2 with several matching policies. See `set_alarm1_date`. - Select the square-wave frequency. See `set_square_wave_frequency`.
- Read whether alarms 1 or 2 have matched. See `has_alarm1_matched`. - Enable and disable the 32kHz output. See `enable_32khz_output`.
- Clear flag indicating that alarms 1 or 2 have matched. See `clear_alarm1_matched_flag`. - Enable and disable the 32kHz output when battery powered. See `enable_32khz_output_on_battery`.
- Enable and disable alarms 1 and 2 interrupt generation. See `enable_alarm1_interrupts`. - Alarms:
- Enable and disable the 32kHz output when battery-powered. See `enable_32khz_output_on_battery`. - Set alarms 1 and 2 with several matching policies. See `set_alarm1_date`.
- Set the temperature conversion rate. See `set_temperature_conversion_rate`. - Read whether alarms 1 or 2 have matched. See `has_alarm1_matched`.
- Enable and disable the temperature conversions when battery-powered. See `enable_temperature_conversions_on_battery`. - Clear flag indicating that alarms 1 or 2 have matched. See `clear_alarm1_matched_flag`.
- Enable and disable alarms 1 and 2 interrupt generation. See `enable_alarm1_interrupts`.
- Temperature conversion:
- Read the temperature. See `get_temperature`.
- Force a temperature conversion and time compensation. See `convert_temperature`.
- Set the temperature conversion rate. See `set_temperature_conversion_rate`.
- Enable and disable the temperature conversions when battery-powered. See `enable_temperature_conversions_on_battery`.
## The devices ## The devices

View File

@ -7,23 +7,26 @@
//! - Read and set date and time in 12-hour and 24-hour format. See: [`get_datetime`]. //! - Read and set date and time in 12-hour and 24-hour format. See: [`get_datetime`].
//! - Read and set date and time individual elements. For example, see: [`get_year`]. //! - Read and set date and time individual elements. For example, see: [`get_year`].
//! - Enable and disable the real-time clock. See: [`enable`]. //! - Enable and disable the real-time clock. See: [`enable`].
//! - Read the temperature. See [`get_temperature`].
//! - Force a temperature conversion and time compensation. See [`convert_temperature`].
//! - Read the busy status. See [`is_busy`]. //! - Read the busy status. See [`is_busy`].
//! - Read whether the oscillator is or has been stopped. See [`has_been_stopped`]. //! - Read whether the oscillator is or has been stopped. See [`has_been_stopped`].
//! - Clear the has-been-stopped flag. See [`clear_has_been_stopped_flag`]. //! - Clear the has-been-stopped flag. See [`clear_has_been_stopped_flag`].
//! - Set and read the aging offset. See [`set_aging_offset`]. //! - Set and read the aging offset. See [`set_aging_offset`].
//! - Enable and disable the 32kHz output. See [`enable_32khz_output`].
//! - Select the function of the INT/SQW output pin. See [`use_int_sqw_output_as_interrupt`]. //! - Select the function of the INT/SQW output pin. See [`use_int_sqw_output_as_interrupt`].
//! - Enable and disable the square-wave generation. See [`enable_square_wave`]. //! - Wave generation:
//! - Select the square-wave frequency. See [`set_square_wave_frequency`]. //! - Enable and disable the square-wave generation. See [`enable_square_wave`].
//! - Set alarms 1 and 2 with several matching policies. See [`set_alarm1_date`]. //! - Select the square-wave frequency. See [`set_square_wave_frequency`].
//! - Read whether alarms 1 or 2 have matched. See [`has_alarm1_matched`]. //! - Enable and disable the 32kHz output. See [`enable_32khz_output`].
//! - Clear flag indicating that alarms 1 or 2 have matched. See [`clear_alarm1_matched_flag`]. //! - Enable and disable the 32kHz output when battery powered. See [`enable_32khz_output_on_battery`].
//! - Enable and disable alarms 1 and 2 interrupt generation. See [`enable_alarm1_interrupts`]. //! - Alarms:
//! - Enable and disable the 32kHz output when battery powered. See [`enable_32khz_output_on_battery`]. //! - Set alarms 1 and 2 with several matching policies. See [`set_alarm1_date`].
//! - Set the temperature conversion rate. See [`set_temperature_conversion_rate`]. //! - Read whether alarms 1 or 2 have matched. See [`has_alarm1_matched`].
//! - Enable and disable the temperature conversions when battery-powered. See [`enable_temperature_conversions_on_battery`]. //! - Clear flag indicating that alarms 1 or 2 have matched. See [`clear_alarm1_matched_flag`].
//! - Enable and disable alarms 1 and 2 interrupt generation. See [`enable_alarm1_interrupts`].
//! - Temperature conversion:
//! - Read the temperature. See [`get_temperature`].
//! - Force a temperature conversion and time compensation. See [`convert_temperature`].
//! - Set the temperature conversion rate. See [`set_temperature_conversion_rate`].
//! - Enable and disable the temperature conversions when battery-powered. See [`enable_temperature_conversions_on_battery`].
//! //!
//! [`get_datetime`]: struct.Ds323x.html#method.get_datetime //! [`get_datetime`]: struct.Ds323x.html#method.get_datetime
//! [`get_year`]: struct.Ds323x.html#method.get_year //! [`get_year`]: struct.Ds323x.html#method.get_year